A product of VULCAN-HART LOUISVILLE, KY 40201-0696
F25213 (May 2006)
- NOTICE -
This Manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly
qualified. If you have attended a Vulcan Service School for this
product, you may be qualified to perform all the procedures
described in this manual.
This manual is not intended to be all encompassing. If you have
not attended a Vulcan Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Vulcan Service Technician.
Reproduction or other use of this Manual, without the express
written consent of Vulcan, is prohibited.
C24EA3 BASIC SHOWN
SERVICE MANUAL
C24EA SERIES
ATMOSPHERIC
STEAMERS
C24EA3 208/240V PRO
C24EA3 480V PRO
C24EA5 208/240V PRO
C24EA5 480V PRO
C24EA3 208/240V BASIC
C24EA3 480V BASIC
C24EA5 208/240V BASIC
C24EA5 480V BASIC
ML-136037
ML-136044
ML-136038
ML-136047
ML-136043
ML-136045
ML-136046
ML-136048
For additional information on Vulcan-Hart Company or to locate an authorized
parts and service provider in your area, visit our website at www.vulcanhart.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 51 52

Shrnutí obsahu

Strany 1 - SERVICE MANUAL

A product of VULCAN-HART LOUISVILLE, KY 40201-0696F25213 (May 2006)- NOTICE -This Manual is prepared for the use of trained Vulcan ServiceTechnicians

Strany 2 - TABLE OF CONTENTS

MODEL C24EA - DOORF25213 (May 2006) Page 10 of 52LATCH ASSEMBLYRemoval and Disassembly1. Separate outer door housing assembly frominner door panel as

Strany 3 - MODELS COVERED

MODEL C24EA - DOORF25213 (May 2006)Page 11 of 522. Install outer door housing assembly as outlinedin DOOR HANDLE.3. Check opening and closing operati

Strany 4 - SPECIFICATIONS

MODEL C24EA - DRAIN BOXF25213 (May 2006) Page 12 of 52CLOSE-UP FROM RIGHT SIDE OF STEAMERAdjustment1. Reinstall striker with slot pointing upward and

Strany 5 - LUBRICATION

MODEL C24EA - COOKING COMPARTMENTF25213 (May 2006)Page 13 of 52PROFESSIONAL MODEL SHOWNCOOKING COMPARTMENTWARNING: DISCONNECT THE ELECTRICAL POWER TO

Strany 6 - COVERS AND PANELS

MODEL C24EA - COOKING COMPARTMENTF25213 (May 2006) Page 14 of 528. Remove the screws securing front panel tolower louvered panel.9. Remove the nuts s

Strany 7 - REAR PANEL

MODEL C24EA - THERMOSTATSF25213 (May 2006)Page 15 of 52THERMOSTATSHOLD THERMOSTATWARNING: DISCONNECT THEELECTRICAL POWER TO THEMACHINE AND FOLLOW LOC

Strany 8

MODEL C24EA - THERMOSTATSF25213 (May 2006) Page 16 of 52Installation1. Insert capillary bulb through large compressionnut.A. Route capillary bulb thr

Strany 9 - DOOR HANDLE

MODEL C24EA - TIMERF25213 (May 2006)Page 17 of 52TIMERWARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOWLOCKOUT / TAGOUT PROCEDURES.R

Strany 10 - LATCH ASSEMBLY

MODEL C24EA - HEATING ELEMENTF25213 (May 2006) Page 18 of 52BASIC MODEL SHOWNHEATING ELEMENTWARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE A

Strany 11 - ADJUSTMENT

MODEL C24EA - HEATING ELEMENTF25213 (May 2006)Page 19 of 529. Reassemble parts removed in reverse order of removal. Tighten heating element screws ev

Strany 12 - DRAIN BOX

MODEL C24EA - GENERALF25213 (May 2006) Page 2 of 52TABLE OF CONTENTSGENERAL ...

Strany 13 - COOKING COMPARTMENT

MODEL C24EA - SUPER HEATERF25213 (May 2006) Page 20 of 52SUPER HEATERWARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOWLOCKOUT / TAGO

Strany 14

MODEL C24EA - SUPER HEATERF25213 (May 2006)Page 21 of 52DIAGNOSTIC CHECKSWARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TEST OR MEASU

Strany 15 - THERMOSTATS

MODEL C24EA - WATER LEVEL CONTROL COMPONENTSF25213 (May 2006) Page 22 of 52WATER LEVEL CONTROL COMPONENTSWATER LEVEL CONTROLSLow Level Cut-Off &

Strany 16 - CONDENSATE THERMOSTAT

MODEL C24EA - WATER LEVEL CONTROL COMPONENTSF25213 (May 2006)Page 23 of 52WATER LEVEL CONTROLBOARDWARNING: DISCONNECT THEELECTRICAL POWER TO THEMACHI

Strany 17 - REMOVAL AND REPLACEMENT

MODEL C24EA - WATER LEVEL CONTROL COMPONENTSF25213 (May 2006) Page 24 of 52NOTE: Perform a steam generator tank cleaning asoutlined under STEAM GENER

Strany 18 - HEATING ELEMENT

MODEL C24EA - WATER LEVEL CONTROL COMPONENTSF25213 (May 2006)Page 25 of 52VIEW FROM LEFT SIDE OF STEAMER6. Reassemble parts removed in reverse order

Strany 19 - DIAGNOSTIC CHECKS

MODEL C24EA - WATER LEVEL CONTROL COMPONENTSF25213 (May 2006) Page 26 of 52NOTE: Apply pipe thread sealant to plumbingthreads before assembly.7. Reas

Strany 20 - SUPER HEATER

MODEL C24EA - WATER LEVEL CONTROL COMPONENTSF25213 (May 2006)Page 27 of 525. Disconnect the drain and drain flush hoses fromthe Tee located below the

Strany 21

MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDSF25213 (May 2006) Page 28 of 52SWITCHES, BUZZER AND SOLENOIDSON/OFF SWITCHWARNING: DISCONNECT THEELECTRIC

Strany 22 - WATER LEVEL CONTROLS

MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDSF25213 (May 2006)Page 29 of 523. Push handle fully in and keep in position.4. Position plunger of on/off

Strany 23 - WATER LEVEL PROBES

MODEL C24EA - GENERALF25213 (May 2006)Page 3 of 52GENERALINTRODUCTIONThis manual is applicable to the models and ML numbers listed on the cover page

Strany 24 - WATER SOLENOID VALVES

MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDSF25213 (May 2006) Page 30 of 52A. Close door.B. Push switch up against switch linkage asfar as possible.C

Strany 25 - MANUAL DRAIN VALVE (BASIC)

MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDSF25213 (May 2006)Page 31 of 526. Perform pressure switch Check.CheckNOTE: Pressure can be checked with th

Strany 26 - (PROFESSIONAL)

MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDSF25213 (May 2006) Page 32 of 52C. Repeat clamping of steam outlet hose atotal of three times to find the

Strany 27

MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDSF25213 (May 2006)Page 33 of 52A. Install valve with the inlet (ON) side ofvalve connected to the back pan

Strany 28 - ON/OFF SWITCH

MODEL C24EA - STEAM GENERATOR TANKF25213 (May 2006) Page 34 of 52STEAM GENERATOR TANKWARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLL

Strany 29 - DOOR SWITCH

MODEL C24EA - STEAM GENERATOR TANKF25213 (May 2006)Page 35 of 5210. Remove remaining steam outlet elbow plumbingfrom steam generator tank.11. Remove

Strany 30 - PRESSURE SWITCH

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006) Page 36 of 52ELECTRICAL OPERATIONCOMPONENT FUNCTIONWater Level Control (WLC) Board ... Cont

Strany 31

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006)Page 37 of 52Solenoid (4SOL), Slow Fill ... Primary fill for Basic machines and secon

Strany 32 - VACUUM RELIEF SOLENOID

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006) Page 38 of 52COMPONENT LOCATIONElectrical Control Panel NOTE: Relay K4 and transformer T2 are pre

Strany 33

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006)Page 39 of 52Water Level Control Board

Strany 34 - STEAM GENERATOR TANK

MODEL C24EA - GENERALF25213 (May 2006) Page 4 of 52SPECIFICATIONS NOTE: All C24EA steamers, with exception of 480V steamers, are shipped pre-wired f

Strany 35

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006) Page 40 of 52Front Panel

Strany 36 - ELECTRICAL OPERATION

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006)Page 41 of 52Steam Generator and Back Panel

Strany 37

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006) Page 42 of 52SEQUENCE OF OPERATIONRefer to the correct wiring diagram for model beingserviced whe

Strany 38 - COMPONENT LOCATION

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006)Page 43 of 52B. Time delay relay is energized throughterminals 2 & 3 for set time (90 seconds)

Strany 39 - Water Level Control Board

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006) Page 44 of 52A. No action as internal latching relay (ILR-1)contacts are open.8. Water level reac

Strany 40 - Front Panel

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006)Page 45 of 52WIRING DIAGRAMSHeating Element Wiring

Strany 41

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006) Page 46 of 52

Strany 42 - SEQUENCE OF OPERATION

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006)Page 47 of 52

Strany 43

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006) Page 48 of 52

Strany 44

MODEL C24EA - ELECTRICAL OPERATIONF25213 (May 2006)Page 49 of 52

Strany 45 - WIRING DIAGRAMS

MODEL C24EA - GENERALF25213 (May 2006)Page 5 of 52Other chemical properties in water supplies can also affect good steam generation and vary from wi

Strany 46

MODEL C24EA - TROUBLESHOOTINGF25213 (May 2006) Page 50 of 52TROUBLESHOOTINGSYMPTOM POSSIBLE CAUSESCompartment leaks water around door. 1. Unit not le

Strany 47

MODEL C24EA - TROUBLESHOOTINGF25213 (May 2006)Page 51 of 52- N O T E S -

Strany 48

MODEL C24EA - CONDENSED SPARE PARTS LISTF25213 (May 2006) Printed in U.S.A.CONDENSED SPARE PARTS LISTC24EAPART NO. DESCRIPTION Basic Professional Qty.

Strany 49

MODEL C24EA - COVERS AND PANELSF25213 (May 2006) Page 6 of 52RIGHT SIDE SHOWNCOVERS AND PANELSWARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE

Strany 50 - TROUBLESHOOTING

MODEL C24EA - COVERS AND PANELSF25213 (May 2006)Page 7 of 52SCREW LOCATIONREAR PANELWARNING: DISCONNECT THEELECTRICAL POWER TO THEMACHINE AND FOLLOW

Strany 51 - - N O T E S

MODEL C24EA - DOORF25213 (May 2006) Page 8 of 52DOORWARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOWLOCKOUT / TAGOUT PROCEDURES.REM

Strany 52 - CONDENSED SPARE PARTS LIST

MODEL C24EA - DOORF25213 (May 2006)Page 9 of 52DOOR HANDLERemoval1. Open door.2. Remove screws from top and bottom of doorassembly.3. Pull outer door