A product of
VULCAN-HART LOUISVILLE, KY 40201-0696
Form 24643 (MARCH 1999)
- NOTICE -
This Manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly
qualified. If you have attended a Vulcan Service School for this
product, you may be qualified to perform all the procedures
described in this manual.
This manual is not intended to be all encompassing. If you have
not attended a Vulcan Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Vulcan Service Technician.
Reproduction or other use of this Manual, without the express
written consent of Vulcan, is prohibited.
VGCTS16 SHOWN ON STAND
SERVICE MANUAL
ROUND COUNTER TOP
TILTING BRAISING PANS
(16 GALLON)
GAS AND ELECTRIC
VGCTS16 ML-114827
VECTS16 ML-114825
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - SERVICE MANUAL

A product of VULCAN-HART LOUISVILLE, KY 40201-0696Form 24643 (MARCH 1999)- NOTICE -This Manual is prepared for the use of trained Vulcan ServiceTechni

Strany 2 - TABLE OF CONTENTS

ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTSPage 10 of 24PAN ASSEMBLYWARNING: DISCONNECT THE ELECTRICALPOWER TO THE MACHINE AT THE

Strany 3 - INTRODUCTION

ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTSPage 11 of 245. Unbolt the braising pan from the mountingsurface or stand.6. Lay the br

Strany 4 - SPECIFICATIONS

ROUND TILTING BRAISING PANS - SERVICE PROCEDURES AND ADJUSTMENTSPage 12 of 24SERVICE PROCEDURES AND ADJUSTMENTSWARNING: CERTAIN PROCEDURES IN THIS SE

Strany 5 - ILLUSTRATION - ELECTRIC MODEL

ROUND TILTING BRAISING PANS - SERVICE PROCEDURES AND ADJUSTMENTSPage 13 of 24FLAME SENSE PROBE(Gas Model)WARNING: THE FOLLOWING STEPS REQUIREPOWER TO

Strany 6 - ILLUSTRATION - GAS MODEL

ROUND TILTING BRAISING PANS - SERVICE PROCEDURES AND ADJUSTMENTSPage 14 of 24HOT SURFACE IGNITOR(GAS MODEL)1. Check to see if hot surface ignitor is

Strany 7 - (Electric Model)

ROUND TILTING BRAISING PANS - SERVICE PROCEDURES AND ADJUSTMENTSPage 15 of 24PotentiometerPerform the following test procedure to verify thepotentiom

Strany 8

ROUND TILTING BRAISING PANS - ELECTRICAL OPERATIONPage 16 of 24ELECTRICAL OPERATIONCOMPONENT FUNCTIONHeater Contactors ... Controls power to hea

Strany 9 - HEATER CONTACTORS

ROUND TILTING BRAISING PANS - ELECTRICAL OPERATIONPage 17 of 24Gas Model1. Conditions.A. Unit connected to correct voltage, polarityis correct and is

Strany 10 - PAN ASSEMBLY

ROUND TILTING BRAISING PANS - ELECTRICAL OPERATIONPage 18 of 24SCHEMATIC DIAGRAMSElectric Model

Strany 11 - LIMIT SWITCH (Gas Model)

ROUND TILTING BRAISING PANS - ELECTRICAL OPERATIONPage 19 of 24Gas Model

Strany 12 - ADJUSTMENT (Gas Model)

ROUND TILTING BRAISING PANSPage 2 of 24TABLE OF CONTENTSGENERAL... 3Introdu

Strany 13 - (Gas Model)

ROUND TILTING BRAISING PANS - ELECTRICAL OPERATIONPage 20 of 24WIRING DIAGRAMSElectric Model (208/240V)

Strany 14 - HOT SURFACE IGNITOR

ROUND TILTING BRAISING PANS - ELECTRICAL OPERATIONPage 21 of 24Electric Model (480V)

Strany 15 - (ELECTRIC MODEL)

ROUND TILTING BRAISING PANS - ELECTRICAL OPERATIONPage 22 of 24Gas Model

Strany 16 - ELECTRICAL OPERATION

ROUND TILTING BRAISING PANS - TROUBLESHOOTINGPage 23 of 24TROUBLESHOOTINGALL MODELSWARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TES

Strany 17

ROUND TILTING BRAISING PANS - TROUBLESHOOTINGForm 24643 (MARCH 1999) Printed in U.S.A.GAS MODELS ONLYSYMPTOM POSSIBLE CAUSESBurner won’t light. 1. Gas

Strany 18 - SCHEMATIC DIAGRAMS

ROUND TILTING BRAISING PANS - GENERALPage 3 of 24Gas Model ShownGENERALINTRODUCTIONThe Vulcan round tilting braising pan (skillet) is a versatile pie

Strany 19 - Gas Model

ROUND TILTING BRAISING PANS - GENERALPage 4 of 24SPECIFICATIONSElectric Braising PanAMPERAGE1 PHASE 3 PHASEMODELTOTALKW208V 240V 208V 240V 480VVECTS1

Strany 20 - WIRING DIAGRAMS

ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTSPage 5 of 24REMOVAL AND REPLACEMENT OF PARTSRefer to the appropriate illustration for c

Strany 21 - Electric Model (480V)

ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTSPage 6 of 24ILLUSTRATION - GAS MODEL

Strany 22

ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTSPage 7 of 24THERMOSTATS(Electric Model)WARNING: DISCONNECT THE ELECTRICALPOWER TO THE M

Strany 23 - TROUBLESHOOTING

ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTSPage 8 of 24RIGHT AND LEFTCONSOLE COVERWARNING: DISCONNECT THE ELECTRICALPOWER TO THE M

Strany 24 - GAS MODELS ONLY

ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTSPage 9 of 244. Remove the screws securing the high limit tothe underside of the pan.5.